×

lkk

Price: 0 - 100

FORGOT YOUR DETAILS?

GP-Max

Functions

Parallel operation of multiple gensets in island mode

Description

Two or more diesel generating sets in parallel work in the function of supplying the same consumers

Example

Situations where there is no mains supply (camps, construction sites, isolated users)

GP-AMF

Functions

Parallel operation of more gensets as a standby in case of power failure without synchronization unit and network

Description

Two or more diesel generating sets in parallel work in the function of supplying the same consumers after a blackout.

Example

Systems that are extremely critical characteristic and always need to have backup power (hospitals, clinics, sports centers, industrial systems ...)

GM-AMF

Functions

The individual genset as a standby power supply in case of power failure, short term synchronization with the network

Description

In case of power failure gensets starts and takes over consumers. After returning mains first comes to short-term synchronization genset and mains power supply and after that, the genset switches off.

Example

Highly critical systems that have extremely critical characteristic and always need to have backup power (hospitals, clinics, sports centers, industrial systems ...) and where in this "soft return" power supply significantly raises the safety of the system. Also, in the case of GX-Mains control system ensures the functioning of the system in the case of failure or maintenance one of the generator set.

GPM - AMF

Functions

Group of generator set in parallel as a standby power supply in case of power failure, with short-term return synchronization with the mains

Description

Two or more generators in parallel in case of power failure and start taking over consumers. After returning mains first comes to short-term synchronization generator set and main power supply after that the gensets turned off.

Example

Highly critical systems that have extremely critical characteristic and always need to have backup power (hospitals, clinics, sports centers, industrial systems ...) and where in this „soft return“ power supply significantly raises the safety of the system. Also, in the case of GX-Mains control system ensures the functioning of the system in the case of failure or maintenance one of the generator set.

GM-Peak

Functions

Gensets in synchronization with the mains in order to make up peak shaving of the utility.

Description

Role of genset facility is in accepting peak consumption of the facility through synchronization gensets and main power supply.

Example

Situations where users are limited installed power of the mains, as well as in situations where the short-term high pulling power lead to enormous energy bills.

GM-Plus

Functions

Gensets in parallel constant work with the mains

Description

Genset constant sells energy in order to submit the energy to consumers

Example

Cogeneration facility fueled by biogas, natural gas, etc ...

Manage all functions in order to parallel work generator and synchronization with network (synchronization, active division of power between the generator, active power factor control, direct control of generator excitation) as well as monitoring of all electrical and mechanical characteristics of the system operation is entrusted to a single controller based on microprocessor technology and integrated PLC functions. Each module system for parallel operation and synchronization is equipped with this kind of controller. Interconnection between modules is achieved CAN BUS communication reducing the need for traditional complicated system of connection and communication. Also communication between the module and the diesel engine is realized CAN BUS communication, allowing full control over the system and integration into BMS system of the facility.

TOP